User's Manual Part 3

Manual Test Cable Setup continued
DRAFT
SC4812ET BTS Optimization/ATP CDMA LMF
Apr 2001
F-12
Table F-9: Calibrating Test Cable Setup (using the HP PCS Interface)
Step Action
19 After all components are calibrated, reassemble all components together and calculate the total test
setup loss by adding up all the individual losses:
Example: Total test setup loss = 1.4 29.8 20.1 = 51.3 dB.
This calculated value will be used in the next series of tests.
20 Under Screen Controls press the TESTS button to display the TESTS (Main Menu) screen.
21 Select Continue (K2).
22 Select RF Generator Level and set to 119 dBm.
23 Click on Pause for Manual Measurement.
24 Verify the HP8921A Communication Analyzer/83203A CDMA interface setup is as follows (fields
not indicated remain at default):
Verify the GPIB (HPIB) address:
under To Screen, select More
select IO CONFIG
Set HPIB Adrs to 18
set Mode to Talk&Lstn
Verify the HP8921A is displaying frequency (instead of RF channel)
Press the blue
[SHIFT] button, then press the Screen Control [DUPLEX] button; this switches to
the CONFIG (CONFIGURE) screen.
Use the cursor control to set RF Display to Freq
25 Refer toChapter 3 for assistance in setting the cable loss values into the LMF.