Table 2-9: Battery Discharge Test
Step Action
1 Turn the battery test switch on the Meter Alarm Panel, ON (see Figure 2-3). The rectifier output
voltage and current should decrease by approximately 10% as the batteries assume the load. Alarms
for the Meter Alarm Panel may occur.
2 Measure the individual battery string current using the DC current probe. The battery discharge
current in each string should be approximately the same (within +
5 A).
3 Turn Battery Test Switch OFF.
Failure to turn OFF the Battery Test Switch before leaving
the site, will result in low battery capacity and reduce
battery life.
CAUTION
Heat Exchanger Power Up
Table 2-10: Heat Exchanger Power Up
Step Action
1 Turn the Power Cabinet Heat Exchanger breakers ON (seeFigure 2-6 for breaker location).
2 The Heat Exchanger will now go into a 5 minute test sequence. Ensure that the internal and external
fans are operating. Place a hand on the internal and external Heat Exchanger grills to feel for air draft.
2