Bay Level Offset Calibration – continued
DRAFT
SC4812ET BTS Optimization/ATP — CDMA LMF
Apr 2001
3-66
If a successful All Cal/Audit was completed, this
procedure does not need to be performed, as BLO is
downloaded as part of the All Cal/Audit.
NOTE
Prerequisites
Ensure the following prerequisites have been met before proceeding.
BBXs being downloaded are OOS–RAM (yellow).
TX calibration successfully completed
Follow the steps in Table 3-34 to download the BLO data to the BBX2s.
Table 3-34: Download BLO
Step Action
1 Select the BBX2(s) to be downloaded.
2 From the Device menu, select Download BLO.
A status report window displays the result of the download.
NOTE
Selected device(s) do not change color when BLO is downloaded.
3 Click OK to close the status report window.