User's Manual Part 2

Bay Level Offset Calibration continued
Apr 2001
3-63
SC4812ET BTS Optimization/ATP CDMA LMF
DRAFT
The 20 calibration entries for each slot/branch combination must be
stored in order of increasing frequency. If less than 10 points
(frequencies) are calibrated, the largest frequency that is calibrated is
repeated to fill out the 10 points.
Example:
C[1]=384, odd cal entry
= 1 ‘‘calibration point
C[2]=19102, even cal entry
C[3]=777,
C[4]=19086,
.
.
C[19]=777,
C[20]=19086, (since only two cal points were calibrated this
would be repeated for the next 8 points)
When the BBX2 is loaded with BLO data, the cal file data for the
BBX2 is downloaded to the device in the order it is stored in the CAL
file. TxCal data is sent first, C[1] C[60]. BBX2 slot 1s 10
calibration points are sent (C[1] C[20]), followed by BBX2 slot 2s
10 calibration points (C[21] C[40]), etc. The RxCal data is sent next,
followed by the RxDCal data.
Temperature compensation data is also stored in the cal file for each
slot.
Test Equipment Setup:
RF Path Calibration
Follow the steps outlined in Table 3-32 to set up test equipment.
Table 3-32: Test Equipment Setup (RF Path Calibration)
Step Action
NOTE
Verify the GPIB is properly connected and turned on.
! CAUTION
To prevent damage to the test equipment, all transmit (TX) test connections must be via the 30 dB
directional coupler for 800 MHz or via a 30 dB coupler with a 20 dB inline attenuator for 1900 MHz.
1 Connect the LMF computer terminal to the BTS LAN A connector on the BTS (if you have not
already done so). Refer to the procedure in Table 3-6.
If required, calibrate the test equipment per the procedure in Table 3-24.
Connect the test equipment as shown in Figure 3-9 and Figure 3-10.
3