User's Manual Part 2

Isolate Span Lines/Connect LMF continued
Apr 2001
3-5
SC4812ET BTS Optimization/ATP CDMA LMF
DRAFT
Setting the Control Port
Whichever control port is chosen, it must first be set up so the control
port switches match the communication parameters being used by the
control device. If using the rearpanel DTE control port, set the
shelf–address switch SA5 to “up” (leave the switch down for the
rear–panel DCE control port).
For more information, refer to the Kentrox Installation Guide, manual
number 6577538001 which is provided with each CSU.
Plug one of the cables listed below into the Control Port connectors:
Part Number Description of Cable
01–95006–022 (six feet) DB9S to DB–9P
01–95010–022 (ten feet)
The control port cables can be used to connect the shelf to:
A PC using the AT 9pin interface
A modem using the 9pin connector
Other shelves in a daisy chain
Figure 3-1: Back and Front View of the CSU
REF. FW00212
Front View
SLOT 1 SLOT 2
DCE Connector
(Craft Port)
SLOT 1SLOT 2
T1 TERMINAL T1 TERMINAL
CONTROL
PORT
GROUP
ADDRESS
SHELF
ADDRESS
T1 DDS T1 DDS
DTE DCEDATA PORT DATA PORT
Back View
NETWORK NETWORK
To/From
Network
To/From
GLI
To/From
Network
To/From
GLI
3