Manual

Test Equipment Set-up68P09258A31–A
Oct 2003
1X SCt 4812T BTS Optimization/ATP
F-21
Table F-14: Manual Cable Calibration Test Equipment Setup (using the HP PCS Interface)
Step Action
23 Click on Pause for Manual Measurement.
24 Verify the HP8921A Communication Analyzer/83203A CDMA interface setup is as follows (fields
not indicated remain at default):
S Verify the GPIB (HP–IB) address:
under To Screen, select More
select IO CONFIG
Set HP–IB Adrs to 18
set Mode to Talk&Lstn
S Verify the HP8921A is displaying frequency (instead of RF channel)
Press the blue
[SHIFT] button, then press the Screen Control [DUPLEX] button; this switches to
the CONFIG (CONFIGURE) screen.
Use the cursor control to set RF Display to Freq
25 Refer to Table 3-31 for assistance in manually setting the cable loss values into the LMF.
F