Manual

Test Equipment Set-up68P09258A31–A
Oct 2003
1X SCt 4812T BTS Optimization/ATP
F-19
Manual Cable Calibration using HP8921 with HP PCS Interface (HP83236)
NOTE
This calibration method must be executed with great care. Some
losses are measured close to the minimum limit of the power
meter sensor (–30 dBm).
Prerequisites
Ensure the following prerequisites have been met before proceeding:
S Test equipment to be calibrated has been connected correctly for cable
calibration.
S Test equipment has been selected and calibrated.
Refer to Figure F-13 for location of the components on the PCS
Interface and Communications Test Set.
Test Equipment Set-up
Perform the procedure in Table F-14 to calibrate the test equipment
using the HP8921 Cellular Communications Analyzer equipped with the
HP83236 PCS Interface.
Table F-14: Manual Cable Calibration Test Equipment Setup (using the HP PCS Interface)
Step Action
NOTE
Verify that GPIB controller is turned off.
1 Insert HP 83236A Manual Control System card into memory card slot (see Figure F-13).
2 Press the Preset pushbutton.
3 Under Screen Controls, press the TESTS pushbutton to display the TESTS (Main Menu) screen.
4 Position the cursor at Select Procedure Location and select it. In the Choices selection box, select
CARD.
5 Position the cursor at Select Procedure Filename and select it. In the Choices selection box, select
MANUAL.
6 Position the cursor at RUN TEST and select it. HP must be in Control Mode Select YES.
7 If using HP 83236A:
Set channel number=<chan#>:
Position cursor at Channel
Number and select it.
Enter the chan# using the numeric
keypad; press [Enter] and the
screen will go blank.
When the screen reappears, the
chan# will be displayed on the
channel number line.
If using HP 83236B:
Set channel frequency:
Position cursor at Frequency Band and press Enter.
Select User Defined Frequency.
Go Back to Previous Menu.
Position the cursor to 83236 generator frequency and
enter actual RX frequency.
Position the cursor to 83236 analyzer frequency and
enter actual TX frequency.
8 Set RF Generator level:
Position the cursor at RF Generator Level and select it.
Enter –10 using the numeric keypad; press [Enter] and the screen will go blank.
When the screen reappears, the value –10 dBm will be displayed on the RF Generator Level line.
. . . continued on next page