Manual

Verifying and Setting GPIB Address
68P09258A31–A
Oct 2003
1X SCt 4812T BTS Optimization/ATP
F-12
Advantest R3465 Communications Test Set GPIB Address
Refer to Figure F-9 and follow the procedure in Table F-9 to verify and,
if necessary, change the GPIB address for the Advantest R3465.
Figure F-9: R3465 Communications Test Set
BNC
“T”
REF UNLOCK
EVEN
SEC/SYNC IN
CDMA
TIME BASE IN
POWER
OFF
ON
REF FW00337
LCL Shift Preset
GPIB and others
Vernier
Knob
NOTE
This procedure assumes that the test equipment is set up and
ready for testing.
Table F-9: Verify and/or Change Advantest R3465 GPIB Address
Step Action
1 To verify that the GPIB address is set correctly, perform the following:
1a Press SHIFT then PRESET.
1b Press LCL.
1c Press the GPIB and Others CRT menu key to view the current address.
2 If the current GPIB address is not set to 18, perform the following to change it:
2a Turn the vernier knob as required to select 18.
2b Press the vernier knob to set the address.
3 To return to normal operation, press Shift and Preset.
F