Manual
FRU Optimization/ATP Test Matrix68P09258A31–A
Oct 2003
1X SCt 4812T BTS Optimization/ATP
C-5
Table C-3: SC 4812T BTS Optimization and ATP Test Matrix
Doc
Tbl
#
RFDS
Switch Card
Power Supply Modules
LPA Bandpass Filter
LPA
LPA Trunking Backplane
GLI
GPS
LFR/HSO
CSM
MCC
BBX
C–CCP Backplane
CIO
MPC/EMPC
TX Cables
RX Cables
RX Filter
Directional Coupler (TX)
Directional Coupler (RX)
Description
page
Table 3-37 3-92
TX Path Calibration 4 4 4
1 1
4
* 3 3
4
7
Table 3-38 3-94
Download Offsets to BBX
4 4 1 4 *
Table 3-39 3-96
TX Path Calibration Audit 4
4 4 1 1 4 * 3 3 4 7
Table 3-48 3-107
RFDS Path Calibration
Procedure (see Note [)
6 6
5
4
1 1
6
* 3 3
4
6
[
RFDS Path Calibration should be performed at initial BTS installation AND after replacement of the RFDS FRU.
RFDS Path Calibration is NOT required for other FRU replacement but may be used as an additional fault isolation tool.
Table 4-1 4-9
Spectral Purity TX Mask ATP 4 4
1
4
* * * * *
Table 4-1 4-9
Waveform Quality (rho) ATP 4 4
* 1
4
* * * * * *
Table 4-1 4-9
Pilot Time Offset ATP 4 4
* 1
4
* * * * * *
Table 4-1 4-9
Code Domain Power / Noise
Floor
4 4
1
4
8 8 8 8 * * * *
Table 4-1 4-9
FER Test
5 5 5 5 2 2 5 8 8 8 8 * 7
* Perform if necessary for additional fault isolation, repair assurance, or site certification.
1 Perform on all carrier and sector TX paths to the C–CCP cage.
2 Perform on all carrier and sector RX paths to the C–CCP cage.
3 Perform on all primary and redundant TX paths of the affected carrier.
4 Perform on the affected carrier and sector TX paths. (BBXR replacement affects all carrier and sector TX
paths.)
5 Perform on the affected carrier and sector RX paths. (BBXR replacement affects all carrier and sector RX
paths.)
6 Perform on all RF paths of the affected carrier and sector (RFDS replacement affects all carriers.)
7 Perform with redundant BBX for all sectors on all carriers.
8 Verify performance by performing on one sector of one carrier only.
C