Manual
Optimization (Pre–ATP) Data Sheets
68P09258A31–A
Oct 2003
1X SCt 4812T BTS Optimization/ATP
A-12
Table A-11: TX BLO Calibration (3–S: 2–C Adjacent Channels)
OK CommentsSpecificationParameter
−
BBX–7, ANT–4 = dB
BBX–r, ANT–4 = dB
−
Calibrate
carrier 2
TX Bay Level Offset = 42 dB (typical),
38 dB (minimum) prior to calibration
BBX–8, ANT–5 = dB
BBX–r, ANT–5 = dB
−
BBX–9, ANT–6 = dB
BBX–r, ANT–6 = dB
−
BBX–1, ANT–1 = dB
BBX–r, ANT–1 = dB
−
Calibration
Audit
carrier 1
0 dB (+0.5 dB) for gain set resolution
post calibration
BBX–2, ANT–2 = dB
BBX–r, ANT–2 = dB
−
carrier 1
BBX–3, ANT–3 = dB
BBX–r, ANT–3 = dB
−
BBX–7, ANT–4 = dB
BBX–r, ANT–4 = dB
−
Calibration
Audit
carrier 2
0 dB (+0.5 dB) for gain set resolution
post calibration
BBX–8, ANT–5 = dB
BBX–r, ANT–5 = dB
−
carrier 2
BBX–9, ANT–6 = dB
BBX–r, ANT–6 = dB
Comments:________________________________________________________
__________________________________________________________________
3–Carrier Adjacent Channels
4–Carrier Adjacent Channels
Table A-12: TX BLO Calibration (3–S: 3– or 4–C Adjacent Channels)
OK Parameter Specification Comments
−
BBX–1, ANT–1 = dB
BBX–r, ANT–1 = dB
−
Calibrate
carrier 1
TX Bay Level Offset = 42 dB (+4 dB)
prior to calibration
BBX–2, ANT–2 = dB
BBX–r, ANT–2 = dB
−
BBX–3, ANT–3 = dB
BBX–r, ANT–3 = dB
. . . continued on next page