User's Manual Part 2
Test Set Calibration – continued
DRAFT
Mar 2001
3-61
SCt4812T CDMA BTS Optimization/ATP
Table 3-28: Calibrating RX Cables Using a Signal Generator and Spectrum Analyzer
ActionStep
5 Calibration factor = A – B
Example: Cal = –12 dBm – (–14 dBm) = 2 dBm
NOTE
The short test cable is used for test equipment setup calibration only. It is not be part of the final
test setup. After calibration is completed, do not re-arrange any cables. Use the equipment setup,
as is, to ensure test procedures use the correct calibration factor.
Figure 3-18: Calibrating Test Equipment Setup for RX ATP Test
(using Signal Generator and Spectrum Analyzer)
Spectrum
Analyzer
Signal
Generator
A
B
Spectrum
Analyzer
SHORT
TEST
CABLE
SHORT TEST
CABLE
CONNECTION TO THE HP PCS
INTERFACE OUTPUT PORT
DURING RX MEASUREMENTS.
Signal
Generator
BULLET
CONNECTOR
LONG
CABLE 2
CONNECTION TO THE RX PORTS
DURING RX MEASUREMENTS. FW00294
3