User's Manual Part 2

Test Equipment Setup
DRAFT
SCt4812T CDMA BTS Optimization/ATP
Mar 2001
3-44
Connecting Test Equipment to
the BTS
All test equipment is controlled by the LMF via an IEEE488/GPIB bus.
The LMF requires each piece of test equipment to have a factory set
GPIB address. If there is a communications problem between the LMF
and any piece of test equipment, verify that the GPIB addresses have
been set correctly (normally 13 for a power meter and 18 for a CDMA
analyzer).
The following equipment is required to perform optimization:
LMF
Test set
Directional coupler and attenuator
RF cables and connectors
Refer to Table 3-22 for an overview of connections for test equipment
currently supported by the LMF. In addition, see the following figures:
Figure 3-11 and Figure 3-12 show the test set connections for TX
calibration.
Figure 3-13 and Figure 3-14 show the test set connections for
optimization/ATP tests.
Figure 3-15 and Figure 3-16 show typical TX and RX ATP setup with
a directional coupler (shown with and without RFDS).
Supported Test Sets
Optimization and ATP testing may be performed using one of the
following test sets:
CyberTest
Advantest R3465 and HP 437B or Gigatronics Power Meter
HewlettPackard HP 8935
HewlettPackard HP 8921 (W/CDMA and PCS Interface for
1.7/1.9 GHz) and HP 437B or Gigatronics Power Meter
Spectrum Analyzer (HP8594E) optional
Rubidium Standard Timebase optional
To prevent damage to the test equipment, all TX test
connections must be through the directional coupler and
in-line attenuator as shown in the test setup illustrations.
CAUTION
3