User's Manual Part 2
Using CDMA LMF – continued
DRAFT
Mar 2001
3-21
SCt4812T CDMA BTS Optimization/ATP
Table 3-7: BTS GUI Login Procedure
Step Action
3 If no base stations are displayed in the Available Base Stations pick list, double click on the CDMA
icon.
4 Click on the desired BTS number.
5 Click on the Network Login tab (if not already in the forefront).
6 Enter the correct IP address (normally 128.0.0.2 for a field BTS) if not correctly displayed in the IP
Address box.
NOTE
128.0.0.2 is the default IP address for MGLI–1 in field BTS units. 128.0.0.1 is the default IP address
for MGLI–2.
7 Type in the correct IP Port number (normally 9216) if not correctly displayed in the IP Port box.
8 Change the Multi-Channel Preselector (from the Multi-Channel Preselector pick list), normally
MPC, corresponding to your BTS configuration, if required.
NOTE
When performing RX tests on expansion frames, do not choose EMPC if the test equipment is
connected to the starter frame.
9 Click on the Use a Tower Top Amplifier, if applicable.
10
Click on Login.
A BTS tab with the BTS is displayed.
NOTE
If you attempt to login to a BTS that is already logged on, all devices will be gray.
There may be instances where the BTS initiates a log out due to a system error (i.e., a device
failure).
If the MGLI is OOS_ROM (blue), it will have to be downloaded with code before other devices can
be seen.
If the MGLI is OOS–RAM (yellow), it must be enabled before other installed devices can be seen.
3