User's Manual

Preparing the LMF – continued
SC 4812T CDMA BTS Optimization/ATP
May 2000
3-16
Table 3-8: Pinging the Processors
Step Action
1 If you have not already done so, connect the LMF to the BTS (see Table 3-2 on page 3-5).
2 From the Windows desktop, click the Start button and select Run.
3 In the Open box, type ping and the MGLI IP address (for example, ping 128.0.0.2).
NOTE
128.0.0.2 is the default IP address for MGLI–1 in field BTS units. 128.0.0.1 is the default IP address
for MGLI–2.
4 Click on the OK button.
5 If the connection is successful, text similar to the following is displayed:
Reply from 128 128.0.0.2: bytes=32 time=3ms TTL=255
If there is no response the following is displayed:
Request timed out
If the MGLI fails to respond, reset and perform the ping process again. If the MGLI still fails to
respond, typical problems are shorted BNC to inter-frame cabling, open cables, crossed A and B link
cables, missing 50–Ohm terminators, or the MGLI itself.