User's Manual

Troubleshooting – Transmit ATP – continued
May 2000
6-9
SC 4812T CDMA BTS Optimization/ATP
Cannot Perform Code Domain
Power and Noise Floor
Measurement
Perform the procedure in Table 6-12 to troubleshoot a code domain and
noise floor measurement failure.
Table 6-12: Troubleshooting Code Domain Power and Noise Floor Measurement Failure
Step Action
1 Verify presence of RF signal by switching to spectrum analyzer screen.
2 Verify PN offset displayed on analyzer is same as PN offset being used in the CDF file.
3 Disable and re-enable MCC (one or more MCCs based on extent of failure).
Cannot Perform Carrier
Measurement
Perform the procedure in Table 6-13 to troubleshoot a carrier
measurement failure.
Table 6-13: Troubleshooting Carrier Measurement Failure
Step Action
1 Perform the test manually, using the spread CDMA signal. Verify High Stability 10 MHz
Rubidium Standard is warmed up (60 minutes) and properly connected to test set-up.
6