User's Manual

Troubleshooting: Calibration – continued
May 2000
6-7
SC 4812T CDMA BTS Optimization/ATP
Cannot Load BLO
For Load BLO failures see Table 6-7.
Calibration Audit Failure
Follow the procedure in Table 6-9 to troubleshoot a calibration audit
failure.
Table 6-9: Troubleshooting Calibration Audit Failure
Step Action
1 Verify Power Meter is configured correctly (refer to the test equipment setup section of Chapter 3).
2 Re-calibrate the Power Meter and verify it is calibrated correctly with cal factors from sensor head.
3 Verify that no LPA is in alarm state (rapidly flashing red LED). Reset the LPA by pulling the
circuit breaker, and, after 5 seconds, pushing back in.
4 Verify that no sensor head is functioning properly by checking it with the 1 mW (0 dBm) Power
Ref signal.
5 After calibration, the BLO data must be re-loaded to the BBX2s before auditing. Click on the
BBX2(s) and select Device>Download BLO
Re-try the audit.
6 Verify GPIB adapter is not locked up. Under normal conditions, only 2 green LEDs must be ‘ON’
(Power and Ready). If any other LED is continuously ‘ON’, power-cycle (turn power off and on)
the GPIB Box and retry.
6