Troubleshooting: Installation – continued
May 2000
6-3
SC 4812T CDMA BTS Optimization/ATP
Table 6-2: Troubleshooting a Power Meter Communication Failure
ActionStep
5 Verify the GPIB adapter is not locked up. Under normal conditions, only two green LEDs must be
‘ON’ (Power and Ready). If any other LED is continuously ‘ON’, then power-cycle the GPIB Box
and retry.
6 Verify that the Com1 port is not used by another application.
7 Verify that the communications analyzer is in Talk&Listen, not Control mode.
Cannot Communicate to
Communications Analyzer
Follow the procedure in Table 6-3 to troubleshoot a communications
analyzer communication failure.
Table 6-3: Troubleshooting a Communications Analyzer Communication Failure
Step Action
1 Verify the analyzer is connected to the LMF with GPIB adapter.
2 Verify the cable setup.
3 Verify the GPIB address is set to 18.
4 Verify the GPIB adapter DIP switch settings are correct.
Refer to the Test Equipment setup section starting on page 3–34 for details.
5 Verify the GPIB adapter is not locked up. Under normal conditions, only 2 green LEDs must be
‘ON’ (Power and Ready). If any other LED is continuously ‘ON’, then power-cycle the GPIB Box
and retry.
6 Verify that the Com1 port is not used by another application.
7 If a Hyperterm window is open for MMI, close it.