User's Manual

Prepare to Leave the Site – continued
SC 4812T CDMA BTS Optimization/ATP
May 2000
5-2
Reset All Devices
Reset all devices by cycling power before leaving the site. The
configuration data and code loads could be different from data and code
on the LMF. By resetting all devices, the CBSC can load the proper data
and code when the span is active again.
Follow the procedure in Table 5-2 as required to bring all processor
modules from the OOS to INS mode.
Have the CBSC/MM bring up the site and enable all
devices at the BTS.
IMPORTANT
*
Table 5-2: Enabling Devices
Step Action
1 On the LMF, select the device(s) you wish to enable.
NOTE
The MGLI and CSM must be INS before an MCC can be put INS.
2 Click on Device from the menu bar.
3 Click on Enable from the Device menu.
A status report window is displayed.
NOTE
If a BBX2 is selected, a Transceiver Parameters window is displayed to collect keying
information.
Do not enable the BBX2.
4 Click OK to close the Transceiver Parameters window.
A status report window displays the status of the device.
5 Click OK to close the status report window.
The selected devices that successfully change to INS change color to green.
5