User's Manual

Automated Acceptance Test Procedure – All–inclusive TX & RX – continued
May 2000
4-3
SC 4812T CDMA BTS Optimization/ATP
ATP Test Procedure
There are three different ATP testing options that can be performed to
completely test a BTS. Depending on your requirements, one of the
following ATP testing options should be run.
ATP Testing Option 1
All TX/RX
ATP Testing Option 2
All TX
All RX
ATP Testing Option 3
TX Mask Test
Rho Test
Pilot Time Offset Test
Code Domain Power Test
FER Test
The Full Optimization test can be run if you want the TX
path calibrated before all the TX and RX tests are run.
NOTE
If manual testing has been performed with the HP analyzer,
remove the manual control/system memory card from the
card slot and set the I/O Config to the Talk & Lstn mode
before starting the automated testing.
IMPORTANT
*
Follow the procedure in Table 4-1 to perform any ATP test.
The STOP button can be used to stop the testing process.
NOTE
Table 4-1: ATP Test Procedure
Step Action
1 Select the device(s) to be tested.
2 From the Tests menu, select the test you want to run.
3 Select the appropriate carrier(s) (carrier-bts#-sector#-carrier#) displayed in the Channels/Carrier
pick list.
NOTE
To select multiple items, hold down the <Shift> or <Ctrl> key while making the selections.
. . . continued on next page
4