User's Manual

RFDS Setup and Calibration – continued
May 2000
3-77
SC 4812T CDMA BTS Optimization/ATP
Set RFDS Configuration Data
If an RFDS is installed, the RFDS configuration data must be manually
entered. Perform the procedure in Table 3-42 to set the RFDS
Configuration Data.
Prerequisite
Logged into the BTS.
The entered antenna# index numbers must correspond to
the antenna# index numbers used in the antenna maps.
IMPORTANT
*
Table 3-42: Set RFDS Configuration Data
Step Action
1 Click on the Util menu.
2 Select Edit>RFDS Configuration>TX or RX.
A data entry pop–up window appears.
3 To add a new antenna number, click on the Add Row button, then click in the other columns and enter
the desired data.
4 To edit existing values, click in the data box to be changed and change the value.
NOTE
Refer to the Util >Edit–RFDS Configuration LMF help screen for RFDS configuration data
examples.
5 To delete a row, click on the row and click on the Delete Row button.
6 To save displayed values, click on the Save button.
NOTE
Entered values are used by the LMF as soon as they are saved. You do not have to logout and login.
7 To exit the window, click on the Dismiss button .
NOTE
Values entered/changed after using the Save button are not saved.
3