User Manual

SCCP Backplane Troubleshooting – continued
PRELIMINARY
SC 4812ETL BTS Optimization/ATP
08/15/2000
6-16
Digital Control Problems
No GLI2 Control via LMF (all GLI2s)
Table 6-15: No GLI2 Control via LMF (all GLI2s)
Step Action
1 Check the Ethernet for proper connection, damage, shorts, or
opens.
2 Verify SCCP backplane Shelf ID DIP switch is set correctly.
3 Visually check the master GLI2 connector (both board and
backplane) for damage.
4 Replace the master GLI2 with a known good GLI2.
No GLI2 Control through Span Line Connection (All GLI2s)
Table 6-16: No GLI2 Control through Span Line Connection (Both
GLI2s)
Step Action
1 Verify SCCP backplane Shelf ID DIP switch is set correctly.
2 Verify that the BTS and GLI2s are correctly configured in the
OMCR/CBSC data base.
3 Visually check the master GLI2 connector (both board and
backplane) for damage.
4 Replace the master GLI2 with a known good GLI2.
5 Check the span line inputs from the top of the frame to the
master GLI2 for proper connection and damage.
Table 6-17: MGLI2 Control Good – No Control over Co–located
GLI2
Step Action
1 Verify that the BTS and GLI2s are correctly configured in the
OMCR CBSC data base.
2 Check the ethernet for proper connection, damage, shorts, or
opens.
3 Visually check all GLI2 connectors (both board and
backplane) for damage.
4 Replace the remaining GLI2 with a known good GLI2.
6