User Manual

Troubleshooting: Receive ATP
08/15/2000
6-11
SC 4812ETL BTS Optimization/ATP
PRELIMINARY
Multi–FER Test Failure
Table 6-14: Troubleshooting Multi-FER Failure
n Step Action
1 Verify test equipment set up is correct for a FER test.
2 Verify test equipment is locked to 19.6608 and even second clocks. The yellow
LED (REF UNLOCK) must be OFF.
3 Verify MCCs have been loaded with data and are INS–ACT.
4 Disable and re-enable the MCC (1 or more based on extent of failure).
5 Disable, re-load code and data, and re-enable MCC (one or more MCCs based on
extent of failure).
6 Verify antenna connections to frame are correct based on the directions messages.
6