User Manual
Alarms Testing
08/15/2000
3-85
SC 4812ETL BTS Optimization/ATP
PRELIMINARY
Alarm Verification
The alarms testing should be performed at a convenient point in the
optimization/ATP process, since the LMF is necessary to ensure that the
SC4812ETL is generating the appropriate alarms.
The SC 4812ETL is capable of concurrently monitoring 10 customer
defined input signals and four customer defined outputs, which interface
to the 50–pin punchblock. All alarms are defaulted to “Not Equipped”
during ATP testing. Testing of these inputs is achieved by triggering the
alarms and monitoring the LMF for state–transition messages from the
active MGLI2.
All customer alarms are routed through the 50 pair punchblock located
in the I/O compartment at the back of the frame. Testing is best
accomplished by using a specialized connector that interfaces to the
50–pair punchblock. This connector is wired so that customer return 1 (2
for the B side) is connected to every input, CDI 0 through CDI 17.
Alarm Reporting Display
The Alarm Monitor window can be displayed to list alarms that occur
after the window is displayed. To access the Alarm Monitor window,
select Util>Alarm Monitor.
The following buttons are included.
S The Options button allows for a severity level (Warning, Minor, and
Major) selection. The default is all levels. To change the level of
alarms reported click on the Options button and highlight the desired
alarm level(s). To select multiple levels press the Ctrl key (for
individual selections) or Shift key (for a range of selections) while
clicking on the desired levels.
S The Pause button can be used to pause/stop the display of alarms.
When the Pause button is clicked the name of the button changes to
Continue. When the Continue button is click the display of alarms
will continue. Alarms that occur between the time the Pause button is
clicked and the Continue button is clicked will not be displayed.
S The Clear button can be used to clear the Alarm Monitor display.
New alarms that occur after the Clear button is clicked will be
displayed.
S The Dismiss button is used to dismiss/close the Alarm Monitor
display.