Installation Instructions
SU Cabling – continued
DEC 2000
6-47
SCt300 BTS Hardware Installation, ATP and FRU Procedures
PRELIMINARY
Table 6-39: Picocell Expansion Kit for Units 3 to 4 Current 2M MIBs B and C – T448AV
Cable Qty. Motorola Part
Number
Description
n/a 2 5882106P01 50 Ohm Antenna Terminator
A 1 3087701C02 Ground cable, 8 -AWG, insulated copper wire. Requires one ring lug
connector.
E 1 3087707C03 MIB A cable (current, 2m; micro)
F 1 3087707C04 MIB B cable (long, 2m)
G 2 3087707C05 MIB C cable (long, 2m)
Q 1 3088120C01 Long SU RF Cable
Table 6-40: Picocell Expansion Kit for Units 3 to 4 Longer 5M MIBs B and C – T448AW
Cable Qty. Motorola Part
Number
Description
A 1 3087701C02 Ground cable, 8 -AWG, insulated copper wire. Requires one ring lug
connector.
H 1 3087707C06 MIB A cable (long, 2m; pico)
I 1 3087707C07 MIB B cable (long, 5m)
J 2 3087707C08 MIB C cable (long, 5m)
Q 1 3088120C01 Long SU RF Cable
Procedure to Install SU Cabling
for Single Unit
Table 6-41 gives the procedure to install the SU cable on one MicroCell
or Picocell. Figure 6-33 shows the location of the cable connectors on
the unit.
Table 6-41: Install the SU Cable on One MicroCell or PicoCell
Step Action
1 Connect cable P to the SU RF and the SU1 connectors of the
unit.
2 Torque the connectors at each end of the cable to 9 in–lb. Use
a 5/16–in. breakaway torque wrench.
6