User's Manual
Installingthe700MHzRRHChapter5:InstallationoftheRRH
Procedure5-1700MHzRRHwallmountconguration(Continued)
Step 2
Step 4
NOTE
Ensurethataqualiedstructuralengineerveriesthewall
structureandwall-mountinstallationfortheweightofthe
installationunderadverseconditionsintheinstallationarea.
3
Hangthewallmountbracket,insertingthetwoM8boltsintothekeyhole
slots.Slidethebracketintothenallocation.
4
InserttwoM8boltsinthebottomtwoslotsandtightenthemusinga13mm
socket.Tightentheinitialtwoboltsinstalledinstep2usinga13mmsocket.
NOTE
Torquesettingforboltsmustcomplywiththevaluerecommended
bythemanufacturerofthewallanchors.
M8x50boltsareprovided.However ,otherfastenersmaybe
necessarypertherecommendationsofthestructuralengineer.
Continued
5-468P09308A55-6
FEB2010