User's Manual

RRHpowerconnectionsChapter6:CablingoftheRRH
RRHexternalpowersupply
Propersafeguardsmustbeinplacetoinsurecompliancewithregulatoryspecicationsforthe
regionoftheinstall.TwoareasofconcernareElectromagneticInterference(EMI)andSurge
protection.
Surgeprotectionofthedcoutput
Thespecicationsforsurgeprotectionare:
MustbecomplianttoIEC61000-4-5,ClassX5KVat2.5KACommonModeand500Vat
250ADifferentialModeIECcombinedwaveform.
Physicallylocatetheprotectionunitascloseaspossibletowherethedclinecomesinto
thestructure.
MustmeetelectrostaticdischargeperIEC61000–4–2Level4.
Motorolarecommendedsurgeprotectors:
Transtector,partnumber12RICP
EmersonPower ,partnumberDCB-48
Onesurgeprotectorisusedforeachsector .
DCpowerlter(EMIprotection)
ThespecicationsfortheDCpowerlterare:
LimitsfortheconducteddisturbanceatthemainsportsofClassBITEequipmentmeetthe
limitsspeciedinEN55022:2006(derivedfromCISPR22:2005)
DCseries,15Ato125A
General-purposeapplication
Supportsbulkheadandrackmounting
Motorolarecommendsthefollowingpowerlter:
TycoElectronics(CORCOM),partnumber10VN1(6609052–2)
Onepowerlterisusedforeachsector.
RRHdcpowercableconnection
Thefollowingprocedureassumes:
ThecustomerisusingtheMotorolasuppliedRRHdcpowercables.
TheDCPowerFilterandtheDCSurgeSuppressorunitsarelocatedinsidethecustomer
location.
TheDCPowerFilterandtheDCSurgeSuppressorunitsarealreadyinstalledandcabled.
6-468P09308A55-6
FEB2010