User Manual

Table Of Contents
3-18 Configuring, Installing, and Using Base Stations
TVS module connectors
The TVS module has connectors on both its right and left sides.
Base station to TVS connector
The base station connector supplies power and an Ethernet connection to the base
station. Connect cable 597-6013-0xxx to this side of the TVS module.
Note: Use the AUX +48 VDC and AUX ETHERNET connections only if you
need to cut off the circular connector from the power/Ethernet cable (597-
6013-0xxx). For example, you might not be able to use the circular connector
if it cannot fit through a space or hole in a wall at the installation site.
Instead, you may split the cable and put a 6-pin, RJ-11 connector on the
Ethernet wires, and a power connector on the power wires. Then, you will
plug the appropriate connector from the split cable into the corresponding
connector in the TVS module. Table 3.3, “Function of wires in cable 597-
6013-0xxx” on page 17 describes the wires in the cable.
Power supply cable and ISP Ethernet network
connector
The other side of the module has a connector for both an Ethernet cable coming
from your ISP network and for the +48 VDC power coming from a power supply.
Note: To ensure your base station is properly protected from possible lightning
strikes, ensure you plug the power cable coming from your power supply
into this connector in the TVS module. If you plug the power cable into the
Figure 3.4
TVS module connector: Base station connector
POWER / ETHERNET
AUX
+48 VDC
Base
Connection
AUX
ETHERNET
+ -