2 Installation site requirements
Prior to installation of the Nokia InLite system, it is most important that certain
actions have been carried out to ensure installation continuity and safety.
2.1 Checking the site
A number of aspects need to be verified as being satisfactory.
Accessibility
Check the following:
Site safety access is provided
The site is accessible to installation, commissioning and maintenance
personnel.
Grounding points
Check that the grounding point(s) are clearly identified.
Power supplies
Check that all the necessary power points are conveniently located for connection
of the Nokia InLite Main Unit (MU) and Remote Units (RUs).
Each RU requires its own power supply and a connection to the mains may be
required.
Space
Check that there is adequate space for:
Installation work
MU, RU and fibre optic cables.
The recommended spacing distances for the MU and RUs as outlined in
Warnings and Cautions have been taken into account in the site planning.
Temperature and ventilation
Adequate space must be provided around the MU and RUs to ensure that the
system can be maintained within the operating temperature ranges.
Check the following:
The site must guarantee natural ventilation to the system.