Installation Instructions
Environment
DN00283911 © Nokia Corporation 15 (43)
Issue 2 DRAFT 1 - en Nokia Proprietary and Confidential
Note
3.3 Operation
This section defines the environmental conditions during the operation of the
Nokia InLite at locations which are not protected from direct weather influences.
When surveying the prospective sites, consider the values presented in this
section.
Operating conditions are defined as stationary: the equipment is mounted on a
structure, or on a mounting device, or it is permanently placed at a certain site.
The Nokia InLite is not intended for portable use.
3.3.1 ETSI standard for operation
The InLite is Class 3.1 as defined in ETS 300 019-1-4:1992
3.3.2 Climatic conditions for operation
For climatic conditions during operation, the Nokia InLite complies generally
with class 3.1 as presented in Table .
Environmental parameter Value
Low air temperature +5 °C
+41°F
High air temperature 40 °C
104°F
Low relative humidity 5%
High relative humidity 85%
Low absolute humidity
1 g/m
3
High absolute humidity
25 g/m
3
Rain intensity Not applicable
Temperature change rate
(average of 5 minutes)
0.5 °C/min.
0.9 °F/min.
Low air pressure 70 kPa
10.15 psi
High air pressure 106 kPa
15.37 psi