Installation Instructions

System Requirements for Installation and Operation
14 (43) © Nokia Corporation DN00283911
Nokia Proprietary and Confidential Issue 2 DRAFT 1 - en
Table 2. Climatic conditions for transportation
3.2.3 Mechanical conditions for transportation
For mechanical conditions during transportation, the Nokia InLite complies with
ETS 300 019 1-2:1992 class 2.3.
Temperature change air/water +40/+5 °C
+104/+41 °F
Relative humidity, not combined with rapid
temperature changes
95% +40 °C
95% 104 °F
Relative humidity, combined with rapid
temperature changes air/air, at high relative
humidity
95% -40 °C /+30 °C
95% -40 °F/ +86 °F
Absolute humidity, combined with rapid
temperature changes air/air, at high water content
60 g/m
3
+70/+15 °C
60 g/m
3
+158/+59 °F
Low air pressure 70 kPa
10.15 psi
Change of air pressure none
Surrounding air movement 20 m/s
65.6 ft/s
Precipitation, rain 6 mm/min.
0.24 in/min.
Radiation, solar
1120 W/m
2
Radiation, heat
600 W/m
2
Water from sources other than rain 1 m/s
3.28 ft/s
Wetness none
Environmental parameter Value