Instruction Manual
Repair
DN00283717 © Nokia Corporation 15 (26)
Issue 2 DRAFT 1 - en Nokia Proprietary and Confidential
Note
WARNING
WARNING
Note
8. Send the faulty unit to Nokia for repair, using the procedure advised by the
local Nokia agent. The unit should be identified and accompanied by a fault
statement.
3.4 Remote Unit
3.4.1 Localising an RU fault
Normally, an RU fault is located with the use of the InLite Supervisor software
application. However, an RU has two LEDs (green and red) that are visible
externally. The LEDs are illuminated when the RU is in a fault state and not
functioning.
An RU fault is identified using the Supervisor software.
The RU LEDs (2) are located under the cable cover of the RU mounting rack. It
is advisable to remove the cable cover so the two LEDs can be seen properly.
3.4.2 Replacing an RU
General warnings and cautions are given in Warnings and Cautions.
3.4.2.1 To replace a faulty RU IP41
Disconnect the power connector from the RU before performing this
procedure.
Shut down the laser in the LU connected to the RU that is to be replaced.
Respect the laser radiation warnings.
Refer to document Installation
1. Connect the laptop PC to the MU as described in Figure .
2. Start the ISMMan software application.