Installation Instructions
Installation
64 (79) © N okia Corporation D N 00203719
N okia Proprietary and C o n f idential I ssue 2 D RAFT 1 - en Status
Note
5.10 Connecting the power
More information on the power connections is provided in Nokia InLite:
Requirements for Installation and Operation. For more information on the power
cable requirements, refer to Nokia InLite: Product Description.
5.10.1 Remote Unit
The RU can be supplied by a central power supply (-48 VDC) or a lo
c
(110 VAC or 220 VAC). Connect or switch on the power to the RUs.
5.10.2 Main Unit
The Main Unit has a fixed power cable for 110 VAC or 220 VAC power
The appropriate plug should be connected. For more information abo
u
the power supply cable, refer to the Nokia document InLite Product Description.
Switch the Main Unit power on.
5.11 Connecting the local management PC
5.11.1 Connecting the PC
To connect the PC and start the Supervisor Software
1. Connect the LMP cable to the LMP connector of the Main Unit an
d
laptop PC.
2. Start the PC and the Supervisor Software.
For more information about the Supervisor software, refer to the No
k
Commissioning
5.11.2 Checking the alarm status
If the FO cable connections between the RU and MU have been made c
the only alarm which should be active when the software is started
door alarm. This alarm can be deactivated by manually operating th
e
alarm switch (see Figure ) the alarm should then be cancelled.