User's Manual
Grounding principle
Modules are grounded.
Check list
1. Connect the grounding cable to the module
front panel.
2. Route the grounding cable through the cable entry.
3. Connect the other end of the cable to the plinth.
4. Repeat steps 1-3 with all the modules.
Tighten to 3.5-4.2 Nm (2.58-3.10 ft-Ib).
Grounding the modules
1. Route the cables through
cable entries.
2. Fix to cable tie points with
cable ties.
Cable clamp
Cabling
Cable routing and cable ties
Cable entry
8
7
Ground
Antenna
Wall
Stack
Installation examples
Pole
Wall
Ground
Antenna
Pole
Cable Entry
Grounding connections are tightened to the correct torque values.
Caution: Incorrect cables
and seals may not provide
secured environmental
protection.Use only tested
IP65 class cables with seals
provided by Nokia Siemens
Networks.