User's Manual

5-45
1
Connect all base stations in your cell to each other, in a daisy chain manner.
2 Supply power to the entire system, as described in the section,“Powering base stations” on
page 6-61 in this guide.
3 Configure the single base station or the master base stations to use an internal time
synchronization signal:
set airlink timing internal
4 Disable the set airlink afc parameter. You must disable this parameter, which otherwise
would allow a base station to automatically frequency lock to the external pulse from the
GPS.
set airlink afc disabled
5 Store your changes in Flash memory by issuing the
write
command.
6 For changes to take effect, reboot or reset the base station’s power. To reboot, type the
following at the command prompt:
reboot