User's Manual

5-39
Table 5.7 describes the uplink data rate when 16 QAM lite is the modulation method
set system location
This parameter defines the zone to which the base station belongs.
During the design of the network, the access provider defines zones of coverage for the
network. For example, an access provider can divide a metropolitan areas into North, South,
East, West, and Central zones.
In the North zone, the network access provider decides to install three base station cells. All
base stations in this zone—regardless of their cell assignment—have the same zone name of
North.
The network access provider then assigns base stations to a specific zone by using the set
system location command.
Example: set system location North
set system name
The parameter specifies the name of the base station.
For example, the network access provider has three base station cells in the zone called
North. All base stations in this zone—regardless of their cell assignment—have the same
zone name: North.
Using the system name, the network access provider provides a name for each base station.
This system name reflects where the base station is installed in the North zone.
To continue the example, a base station assigned the zone name of “North” is to be installed
near the intersection of 7th street and Randolph avenue. The base station is given the name
sevenandrandolphbase2. This name indicates that this is the second base station installed near
the street. Another base station (also in the North zone) is to be installed near the intersection
of Carmody drive and 45th avenue. It is given the name carmodyand45base1.
Example: set system name SevenandRandolphBase2
set airlink state
This parameter enables the airlink.
After you specify the set airlink channel number, set airlink downlink power, and set
downlink bias parameters, set the airlink state to enabled, so changes can take effect.
Example: set airlink state enabled
You can take the base station off the air by disabling the airlink.
Table 5.7 Uplink data rate for 16-QAM lite modulation method
Bias Uplink all 1 slot 2 slot
0 5,256,608 750,944 1,661,571
1 4,323,964 617,712 1,366,777
2 3,342,912 477,559 1,056,668
3 --- --- ---
4 --- --- ---
5 --- --- ---