Product Overview

Read This Before You Buy: The chart shows the R-value of this insulation.
R means resistance to heat ow. The higher the R-value, the greater the
insulating power. Compare insulation R-values before you buy. There are
other factors to consider. The amount of insulation you need depends
mainly on the climate where you live. Also, your fuel savings from
insulation will depend on climate, the type and size of your structure, the
amount of insulation already in your structure, and your fuel use patterns
and occupancy. If you buy too much insulation, it will cost you more
than you’ll save on fuel. To get the marked R-value, it is essential that
this insulation be installed properly.
1
Foil facings should be covered by a
thermal barrier, please check local building requirements.
System R-Values are calculated for enclosed air-to-air spaces for the specic applications and
orientations as described. The R-Value of reective insulation is application and orientation specic.
Please contact your NOFP representative for a complete table of System R-Values based on dierent
installation methods.
Northwestern Ohio Foam Products, Inc.
725 Enterprise Avenue • Wauseon, OH 43567
800-339-4850 • 419-335-4850 • Fax: 419-335-2380
www.NOFP.com • www.TheBarrier.com
Distributed by:
Tape Edge
New Construction
Post Frame
Easy to use rolls
PRODUCT SPECIFICATIONS
Core
-Solex: ¼” moisture-proof polyethylene (R-Value = 0.92 core only)
-SolexLT: ⁄” moisture-proof polyethylene (R-Value = 0.45 core only)
Face
-White Poly -Foil
-White Woven -Reective
System Thermal R-Values (ft • h • °F/Btu)
Solex
Downwards (7/16” OSB / 2.75 Airspace / Solex / 2.75” Airspace / ½” Gypsum) .............13.4
Upwards (7/16” OSB / 2.75” Airspace / Solex / 2.75 Airspace / ½” Gypsum) ............... 8.0
Horizontal (Vinyl siding / 1” Airspace / Solex / 7/16 OSB) ..............................................5.8
Horizontal (Vinyl siding / 2.75” Airspace / Solex / 2.75” Airspace / ½” Gypsum) .............9.5
SolexLT
Downwards (7/16” OSB / 2.75 Airspace / SolexLT / 2.75” Airspace / ½” Gypsum) .........13.1
Upwards (7/16” OSB / 2.75” Airspace / SolexLT / 2.75” Airspace / ½” Gypsum) ........... 7.5
Horizontal (Vinyl siding / 1” Airspace / SolexLT / 7/16” OSB) ...........................................5.4
Horizontal (Vinyl siding / 2.75” Airspace / SolexLT / 2.75” Airspace / ½” Gypsum)
........ 9.1
Surface Reectivity
-Foil up to 97%
-White N/A
-Reective up to 94%
Flame Spread / Smoke Spread –ASTM E84
-White Poly or White Woven Exposed 0/15
-Reective Exposed 0/10
-Foil Exposed
1
N/A
Usable Temperature 200° F / 93° C
Warning: Solex products have been ASTM E84 tested. It is not recommended that Solex be exposed
to possible ignition sources or open ame during shipping, storage or installation. Caution:
Aluminum foil conducts electricity. Care should be taken around electrical sources and overhead
power lines.