User Manual

濖濣濘激濅濇濈濋激濔濖激濦激濜澳濖瀂瀁濹濼濺瀈瀅濴瀇濼瀂瀁澳濠濴瀁瀈濴濿澳
濄濆澳
the reserved IP addresses, the supported device shall follow the MAC to IP address
mapping shown in Table 3:
Table 3 - CPE Series Product Secondary IP Address
Ethernet MAC address
Reserved Purpose
Secondary
IP
address
XX:XX:XX:XX:XX:00
Invalid IP
A0
192.168.99.160
XX:XX:XX:XX:XX:01
For gateway
A1
192.168.99.161
XX:XX:XX:XX:XX:02
For operator
computer
A2
192.168.99.162
XX:XX:XX:XX:XX:03
For operator
computer
CPE
192.168.99.163
XX:XX:XX:XX:XX:04
For operator
computer
A4
192.168.99.164
XX:XX:XX:XX:XX:FF
Invalid IP
AF
192.168.99.175
Example 2
Device Ethernet MAC address: 00:19:BE:20:03:FF
Secondary IP Address of this device:
192.168.99.175 (FF (HEX) ! AF (HEX) ! 175 (DEC))
3.4. System Info Setting
Figure 8 System Info Setting
1. Click Configuration > System
2. Type in a string up to 255 characters in System Name; this entry
is optional
3. Type in a string up to 64 characters in System NE ID; this entry is
optional
4. Type in a string up to 255 characters in System Location; this entry
is optional
5. Select Power Save PoE checkbox if CPE is powered by a PoE
switch that is compliant with 802.3af only.
6. Click Submit