User's Manual
INSTRUCTIONS MANUAL AUTOMATIC FILTERS
FC/D-DP -FAC/D-DP
 s.r.l.Milano - ITALY
Page 15 of 21
fcd-dp_mi-r2.doc – 
r.2
Proceed as follows to modify :
1.  push the button 
 ESC
2.  push several times the button  until the pointer > points "set param"
3.  push the button   
OK
.
4.  push several times the button  until the display shows the parameter where to make the
modification (B3 - 1 or other)
5.  push the button 
OK
, the blinking cursor will take place on the line of the days (D)
6. by pushing the button  the cursor moves on the positions correspondent to the days of
the week
7.  push the button  to enable/disable
8.  by pushing the button  the cursor moves on the several digits of the hours (lines ON and
OFF)
9.  when the cursor blinks on the digit to modify, push several times the  until the desired
number appears
10. repeat the same operations with other digits, whether required.
11. push the button 
OK
 to confirm the modifications
12. push the button  to visualize other parameters which must be modified, and operate as
explained at above points 5 ÷11, or push the button 
 ESC
 to leave the modification menu
13. push the button   
ESC
 to go back to visualization of service.
7.3.  How to set time of phases, delay, pressure drop value
Proceed as follows to modify :
1.  push the button   
ESC
2.  push several times the button  until the pointed > points "set param"
3.  push the button 
 OK
.
4.  push several times the button  until the parameter to modify is shown (B1 or other)
5.  push the button   
OK
.
6.  by pushing the button , move the cursor on the digit to modify
7.  when the cursor blinks on the digit to modify, push the button  until thge desired digit
appears
8.  repeat the same operations with other digits, whether required
9.  push the button 
OK
 to confirm the modifications
10. proceed as explained for other modifications of other parameter or push the 
ESC
 per to
leave the modification menu
11. push the button  
ESC
 to go back to visualization of service
NOTE:
•
  during the modifications, the normal service is NOT interrupted.
•
  In modification menù, ref. to the timers, the digits visualized on the line (marked
as Ta) underneath the line of the time setting (marked as T), indicate the status
of the present counting of the time related to the selected timer
•
  time basis are :
s = seconds (00,00 ÷ 99,95)
m = minutes (00:00 ÷ 99m:59s)
h = hours (00:00 ÷ 99h:59m)
•
  although the programmer allows to set values up to 19999, in the field of the
max allowable pressure drop (B5), let us remind that the real max allowable
value is 100, correspondent to a pressure drop of 1 bar (=100 kPa = max
allowable value pressure drop across the filter).