Data Sheet

2.0 Application & Notice
This DC to AC inverter is designed for the backlight of 6.4”-15.1”LCD Panel with 1
CCFL Cathode Fluorescent Lamp .
.
Notice:
2.1 For Safety Issue, please keep 4.0mm at least from the metal parts of the system to the
inverter. Or, put a high-voltage insulator between the inverter and the metal parts to
avoid the situation of Hi-POT failure or arcing---etc.
2.2 Don’t twist , deform , drop or knock the inverter during assembly.
2.3 The inverter is usually designed without the case. Please take care about ESD at
anytime.
2.4 Due to the characteristic of Panels, the brightness is sensitive about Temperature. You
must measure it in the same condition and waiting for power on 10~30 minutes.
3.0 Environment Characteristics
3.1 Temperature:
Storage : -25°C ~ 85°C.
Operating : -20°C ~ 75°C
3.2 Humidity:
Storage : 10% ~ 95% RH , non-condensing
Operating: 10% ~ 90% RH , non-condensing
3.3 MTBF: 60’000 Hrs @ 25°C
Distributed by Conrad Electronic SE, Hirschau, Germany