Data Sheet
a. Products in  the  lead when disconnect between AC660V  shall  withstand, 1min without breakdown flash 
over phenomenon; 
b. Product  leads  and  insulated  shell,  between  AC1800V  can  withstand  1S  without  breakdown  flash  over 
phenomenon.(striking current is 0.5mA) 
3.5 Insulation  resistance:  under  normal  conditions,  fuses  and  insulation  shell  insulation  resistance  in  100M  Ω 
above. (used for DC500V meter) 
3.6 Contact resistance:Product contact resistance shall not be more than 50mΩ。 
3.7 High temperature resistant test: The action temperature should keep in 96h in temperature of 50 ° c rated 
movements in air environment. 
3.8 Low temperature resistance test: product should keep in 96h when in air environment - 40 ° c 
3.9 Ant-vibration  test:  thermal  protectors  shall  withstand  amplitude,  frequency  changing  1.5  mm  10  ~  55Hz, 
scanning change cycle 3-5 times/min, vibration direction X,Y,Z, in each direction, each successive 2h vibration. 
3.10 Drop test: products high free fall from 0.7 m. 
3.11 Compression test: products shall stand 1min in100N static pressure. 
3.7,3.8,3.9,3.10,3.11should meet the following requirements: 
a.Disconnect temperature charges in the initial value should be within +7℃ 
b.contact resistance should be below 100mΩ; 
c.appearance should be no obvious deformation; 
d.wires should without cracking damage. 
4 Life 
Products in the rated voltage, current, power factor for 0.7 conditions, plus 4,000 times that the action of 
heat, should satisfy as below: 
a. Disconnect temperature changes in the initial value should be within + 5 ° c, 
b.Contact resistance should be belowin100Mω 
continue experiment in 6000times after action。 