Data Sheet
MD62 Thermal conductor CO
2
Gas sensor
MD62 gas sensor consists of an active element and a reference element with the same resistance,
both elements are placed in a wheatstone bridge circuit, The analyzing gas contents changes, the
overall thermal coefficient of mixed gases changed correspondingly; when the active element meet the
combustible gas, its resistance become smaller, when It meet other gas, , Its resistance become
larger(air background), the bridge circuit output the voltage change, this change increase according to
gas concentration, the reference element as a benchmark while for temperature compensation.
Features
Wide Detecting Range (0—100%VOL)
Linear output signal
Quick response
Good reproducibility and reliable performance
Resistant to toxicosis
Detecting without Oxygen or short of oxygen
Application
Domestic, Industrial spot for CO2、CcL4、freon、Natural
gas, LPG etc detecting.
Structure Basic testing circuit
Specification
Detecting Range 0~100%vol
Working Voltage (V)
3.0±0.1
Working current(mA) @100
10%Methane >12
10%Butane >8
Sensitivity
mV
10%CO
2
>5
linearity(%)
0~5
Response time (90%)
>10sec
Resume time (90%)
>30sec
Using Environment -20-+60℃ <95%RH
Storage Environment -30—+80℃ <95%RH
Dimension(mm) 10×14×18