Use and Care Manual

Adapter Removal:
Option 1
1. Remove grab bar from the adapters by taking out the screws and spacers
.
2. Put masking tape around triangle to prevent scratching surface. Use channel locks and firmly turn the
adapter clockwise applying consistent pressure
3. Remove excess adhesive from surface using a razor knife and wipe with acetone if needed. For rough
surfaces, a coarse brush can also be used.
Safety Warning:
! Follow instructions carefully to ensure proper performance as well as to reduce the chance of injury
! If you have purchased the nie wieder bohren. adapter, be sure to check the stability of the wall prior to mounting. If the
existing wall is old or has any visible water damage or weakness, the performance of the grab bar should be affected
negatively.
! When installed properly on a sturdy surface, the nie wieder bohren. system exceeds the ADA (Americans with
Disabilities Act) requirements for a weight capacity of 250lbs. However, grab bars are not designed to support a person’s
total weight and rather to provide for stability and assistance. Do not stand or sit on the grab bar!
! It is recommended to routinely check your grab bar in order to make sure it is properly secured and no looseness or wall
damage noted.
! The GB00002-NDR adapter kit contains small parts which should be kept out of reach of CHILDERN, PETS and those
NOT APPRISED in the use of this product at all times in order to avoid injuries.
! Do not substitute any other adhesive for use with the nie wieder bohren. system. This is a professional grade adhesive
which was especially designed for this adapter.
! The alcohol cleaning cloth should only be used for its intended purpose. It can only perform sufficiently if opened directly
before use.
! When using cleaners and chemicals like acetone, please observe the manufacturer’s specific safety regulations.
! First Aid:
Skin: Avoid long term contact with the skin. Rinse with running water and soap. Apply replenishing cream.
Eyes: Avoid contact with the eyes as well as with other mucous membranes. Wash with plenty of water immediately and
continue for several minutes, holding eyelid open. Consult a doctor.
If ingested, seek medical advice immediately and show this container or label and/or contact poison control
For further information call 800-961-5804 or go to
http://www.niewiederbohren.de/media/raw/Safety_Data_Sheet_nwb2011_en.pdf for a copy of the MSDS (Material Safety
Data Sheet).