SDS

NIU-48N7A0
K14875
Specification
Security Level
Internal public
File No.
PGG003436
Version
V1.6
All content in this article is confidential information of SCUD. Page
7
of Total
17
Do not distribute without permission.
discharge
overcurrent is the
same as that of
discharge
overcurrent
protection.
Discharge
overcurrent
protection
Protection current
A
23
25
27
When discharge
overcurrent
protected three
times in a row
need remove the
load.
Delay time
s
4
5
8
Recovery
s
Delay 30s or charge or remove load
Discharge
overcurrent
protection
Protection current
A
43
45
47
Delay time
s
0.5
1
2
Recovery
Remove load
Short-circuit
protection
Protection current
A
-
90
-
Delay time
us
50
150
400
Recovery
Remove load
Cells balance
temperature
protection
Protection temperature
75
80
85
Delay time
s
3
5
7
Recovery temperature
45
50
55
Pre-discharge
Opening conditions
1. Main discharge MOS off.
2. BMS is not in short circuit state or undervoltage state.
Closing conditions
1. Main discharge MOS on.
2. BMS is in short circuit state or undervoltage state.
3.
In Pre-discharge state:pre-discharge current 100mA
&
Delay
20s or
pre-discharge current2
00mA & Delay
5s
Recovery time
30s.
4.
Limit current resistance temperature
80℃
Cells balance
Opening conditions
1. Voltage3.8V.
2. On charging state or resting state.
3. 0.5VCells differential50mV.
Closing conditionsAny):
1Discharging state or fault state
2Cells differential20mV or cells differential0.5V.
3Cell voltage3.8V.
4Cells balance temperature80℃
About
temperat
Discharge high
temperature
Alarm temperature
62
65
68
Delay time
s
3
5
7