Manual

Solenoid Upgrade (optional)
The optional Solenoid Upgrade (#15055) is required if the nozzle is to be installed after the intake throttle plate
(as shown), or the uid reservoir is mounted higher then the nozzle. It is highly recommended for trunk-mount
reservoirs.
Finger thread the two 1/8” NPT quick connect ttings into ports labeled (2 or IN) and (1 or OUT) on the sole-
noid. Tighten an additional half turn past nger tight.
Note: Solenoid must be installed Pre-pump to ensure correct operation.
Cut high pressure line at location solenoid is to be installed. Insert ends of cut line into quick connect ttings
of solenoid. The port labeled (2 or IN) is the inlet and the port labeled (1 or OUT) is the outlet. Gently pull on
line to check secure connection. If line pulls out, re-insert farther into tting to engage locking clips. If high
pressure line removal is required, rmly press in metal tting ring to disengage locking clips while pulling hose
from tting.
Connect one of the BLACK wires from solenoid to the RED positive pump wire or the WHITE wire from the
controller. Note that connecting the wire to any other power source other then the pump/controller wire will
result in improper operation of solenoid. Connect the second BLACK wire to a secure chassis ground location.
RIGHTS RESERVED
As our technology expands, we may nd it necessary from time to time to make changes in some of the items
offered in our catalog. Nitrous Express reserves the right to make, without notice, changes in design, material
and speci cations or to make product changes without liability.
PRINTING ERRORS
Every effort has been made to proof all copy prior to printing. However, we do not accept responsibility for
typographical errors either in prices or content.
MAXIMUM LIABILITY
The maximum liability of Nitrous Express in connection with this warranty shall not under any circumstances
exceed the contract price of the product claimed to be defective.