Specifications
No.
1505982
HUGHES PROPRIETARY
Rev.
C
Sheet 25 of 28
Form E75a Hughes Network Systems, LLC
10.5 IMMUNITY
R10-07. The LNA shall meet the immunity requirements specified as detailed in Table 9-3. Immunity requirements
in the European Union are covered by the EMC Directive 2004/108/EC
Table 10-3 Immunity Requirement
EN 55024
(Latest)
Limits and Methods of Measurement of Immunity Characteristics of
Information Technology Equipment
–
Same as
CISPR 22 – Ed. 5 – 2005-04, amd.1 – 2005-07
IEC
61000-4-2 (Latest)
Electromagnetic compatibility (EMC) – Part 4: Testing and Measurement
Techniqu
es –
Section 2: Electrostatic Discharge Immunity Test. Basic EMC
Publication
IEC
61000-4-3 (Latest)
Electromagnetic Compatibility (EMC) – Part 4: Testing and Measurement
Techniques
– Section 3: Radiated, Radio-
Frequency, Electromagnetic Field
Immunity T
est
IEC
61000-4-4 (Latest)
Electromagnetic Compatibility (EMC) – Part 4: Testing and Measurement
Techniques
– Electrical Fast Transient/Burst Immunity Test – Basic EMC
Publication
IEC
61000-4-5 (Latest)
Electromagnetic Compatibility (EMC) – Part 4 Testing and Measurement
Techniques
– section 5: Surge Immunity Test
IEC
61000-4-6 (Latest)
Electromagnetic Compatibility (EMC) – Part 4: Testing and Measurement
Techniques
– Section 6: Immunity to Conducted Disturbances, Induced by
Radio
-Frequency Fields Test –
10.5.1 Surge Immunity
R10-08. The LNA shall survive when subjected to surge immunity testing per IEC 61000-4-5. The test levels are
given in Table 10-4.
Table 10-4. Test Levels in Surge Immunity Testing
Port
Test Level
Common Mode
Differential Mode
Indoor Equipment Interfaces
±4.4 kV
±4.4 kV
10.6 RADIO STANDARDS
R10-09. The LNA supplier shall provide relevant and necessary backup data to Hughes Network Systems as required
for regulatory license applications.