User Instructions

Regulatory Module Integration Instructions
2.2 List of applicable FCC rules
This device complies with part 15.249 of the FCC Rules.
2.3 Summarize the specific operational use conditions
This module can be used in household electrical appliances as well as Intelligent switch ,
Wall-hung switch equipments. The input voltage to the module should be nominally 3.0 to
5.25 VDC ,typical value 5VDC and the ambient temperature of the module should not
exceed 100℃.
This module using only one kind of antennas with maximum gain is 0dBi .Other antenna
arrangement is not covered by this certification.
The antenna is not field replaceable. If the antenna needs to be changed, the certification
should be re-applied.
2.4 Limited module procedures
This module can be used in Intelligent switch, Wall-hung switch, Intruder detect
appliances. Normally host device should provide a power supply in range DC 3.0-5.25V,
typically 5V DC for this module. The limited module manufacturer will reviews detailed test
data or host designs prior to giving the host manufacturer approval.
2.5 Trace antenna designs
Not applicable
2.6 RF exposure considerations
The modular transmitter is authorized to be used in a specific type of host platform
and installed such that it can be operated at clos
er than 20 cm to users or nearby
persons.This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter .