Horizontal
Vertical
Antenna Beam Pattern
10°
20°
30°
40°
50°
60°
70°
80°
90°
100°
110°
120°
130°
140°
150°
160°
170°
180°
190°
200°
210°
220°
230°
240°
250°
260°
270°
280°
290°
300°
310°
320°
330°
340°
350°
-40
-30
-20
-10
0
PD-V11 24.1GHz Microwave Motion Sensor
The PD-V11-H 24.1GHz microwave motion sensor is a K-band Doppler
transceiver module.It is a planar antenna that we independently design
and develop, with good transmission and reception matching in the layout.
The internal layout we recalculated and arranged is more
reasonable.Make the main frequency of the sensor more stable. Suitable
for a wider range of ambient temperatures, these are our design
patents, where V11-H has a higher noise ratio and sensitivity, one-third
higher than the sensitivity of the products on the market.
The V11-M and V11-L can be customized to the user's sensitivity
requirements. This sensor module is ideal for automatic lighting.The security
domain acts as an intrusion detection sensor.
Note1: The radiated emissions is designed to meet FCC rules.
Note2:The Received Signal Strength(RSS) is measured at the total 1 Ways path loss of 70dB.
Note3: The noise voltages are measured from 10Hz to 100Hz at the Output port, inside an Anechoic chamber.
Note4: Pulse operation
Application
Intelligent switch
Intruder detect
Wall-hung switch
-70
-60
-50
Products size
3.4mm
7mm
XXmm
3mm
25mm
20mm
20mm
25mm
Vcc
Signal output
According with FCC Part 15.249
According with EN 62321,ROHS directive - 2011/65/EU
According with REACH directive - 1907/2006/EC
According with EN 300440-V2.1.1EN 624792010
RED directive - 2014/53/EU
Parameter
10-30 μSecPulse Width
3.0 5.0
5.25 VV
cc
Supply Voltage
20 35 38 mACurrent Consumption I
cc
Operation mode
-30-85 +100Max.
Operating Temperature T
op
Storage ambient humidity
-10 +60
Storage temperature T
stg
Notes Min Typ Max Units
Frequency Setting
24.088 24.100 24.115
GHzf
2.0 2.5 3.0 mWRadiated Power (EIRP) P
out
1.5-3 KHzPulse Repetition Frequency
<20 <20 <20 μSecStable time
Powered by PW, it can control the working current at 6-12mA
45%~65% RH