user manual

5
41840-A McAlby Court, Murrieta, CA 92562
(800) 451-9343, email: sales@nimbuswater.com
Push Handle Airgap Faucet
1. Insert polished faucet base and rubber seal onto base of faucet
and insert base assembly down through the sink hole.
2. From underneath the sink, push the 1/4” black drain tubing
aached to the system onto the 1/4” ng located on the faucet
base.
3. Locate the extra piece of 3/8” white tubing and push one end
onto the larger 3/8” ng located on the faucet base.
4. Slide white plasc spacer open-end-up onto the threaded fau-
cet stem (2).
5. Loosely thread the 3/8" washer (3) and mounng lock nut (4)
onto the threaded stem.
6. Thread faucet quick-connect adapter (5) on to threads of faucet
stem. NOTE: This connecon should be hand-ghtened only. Push
one end of 3/8" blue tubing into 3/8" connecon.
8. Posion the faucet to the desired handle orientaon. Slip the
sloed washer (1) between the white plasc spacer and the sink.
Securely hand ghten the mounng nut.
9. Firmly insert spout assembly into the top hole of faucet body
(approximately 1/4"). You may swivel the faucet le or right.
Airgap to system drain
(1/4" black tubing)
Faucet to drain saddle
(3/8" white tubing)
Product water
(1/4" blue tubing)
Metal base plate
Rubber seal
1
2
3
4
5