IVB 3-M/5-M/7-M auto auto auto auto auto Operating Instructions Betriebsanleitung Notice d’utilisation Gebruiksaanwijzing Istruzioni sull’uso Driftsinstruks Bruksanvisning 302001885 C Driftsvejledning Käyttöohje Navodilo za uporabo Uputstvo za rad Prevádzkový návod Provozní návod Instrukcja obsługi Kezelési utasítás Ðóêîâîäñòâî ïî ýêñïëóàòàöèè Instrucciones de manejo Instruções de operação Οδηγίες λειτουργίας Ýþletme kýlavuzu
IVB 3-M IVB 5-M IVB 7-M IVB 3-M 10 3 1 11 14 9 3 auto 4 5 6 8 IVB 5-M 10 1 7 14 9 3 auto auto 4 5 6 1 IVB 7-M 8 2 10 7 14 9 3 auto auto 4 5 12 8 5 6 12 13
IVB 3-M IVB 5-M IVB 7-M english Contents 1 Important safety instructions ............................................................................................2 2 Description 2.1 2.2 Purpose ................................................................................4 Operating elements ..............................................................5 3 Before start-up 3.1 Assembling the cleaner ........................................................5 4 Operation 4.1 4.1.1 4.1.2 4.1.3 4.
IVB 3-M IVB 5-M IVB 7-M english 1 Important safety instructions Symbols used to mark instructions Before using the vacuum cleaner, always read the operating instructions and keep them read- This symbol is used to mark safety instructions that must be observed to prevent damage to the vacuum cleaner and its performance. This symbol is used to mark safety instructions that must be observed to prevent damage to persons.
IVB 3-M IVB 5-M IVB 7-M Precautions and safety regulations when using the vacuum cleaner Dust Class M (medium). The dusts which belong to this class are: dusts with OEL values > 0.1 mg/m³ as well as saw dust. The machine is tested in its entirety by vacuums for this dust class. The maximum degree of permeability is 0.1% and the disposal must be low dust. Before start-up Electrical components Inspect power cord regularly to detect signs of damage, e.g. cracks or ageing.
IVB 3-M IVB 5-M IVB 7-M english Tool socket Use the socket on the vacuum cleaner for the purpose defined in the operating instructions only. Before plugging an appliance into the appliance socket: 1. Switch off the vacuum cleaner 2. Switch off the appliance to Maintenance, cleaning and repair Only carry out maintenance work described in the operating instructions. Always pull out the mains plug before cleaning and maintenance of the vacuum cleaner.
IVB 3-M IVB 5-M IVB 7-M 2.2 Operating elements See fold-out page at the front of these operating instructions. 1 2 3 4 Handle Suction pipe support Accessory holder Applicance switch with suction power control 5 Retaining clamp 6 7 8 9 10 11 Dirt tank Grip to empty tank1) Inlet fitting Appliance socket1) Cable hook Operating knob for filter cleaning1) 12 Tank locks1) 13 Castor with brake 14 Hose diameter setting english 3 Before start-up 3.
IVB 3-M IVB 5-M IVB 7-M english 4.1.3 Connecting electrical appliances To comply with regulations, only approved dust producing tools should be connected. The maximum power consumption of the connected power tool is stated in section 9.4 “Technical data”. Switching on the vacuum cleaner 4.2.1 Switch position “I” Hose ø ø27 ø32 ø38 ø50 27 0 50 The hose diameter and the setting for the suction hose diameter must be the same. 0 36 2 0 3 4.
IVB 3-M IVB 5-M IVB 7-M 4.4 Acoustic warning 4.5 Cleaning the filter element (IVB 3-M) If the acoustic signal sounds again after repeated cleaning, replace the filter element (see section 7.2.5). 1 0 auto I x3 Filter Cleaning System If suction performance drops: 1. Set the suction power to maximum. 2. Close the nozzles or suction hose opening with the palm of your hand. 3. Press the button to start filter cleaning three times.
IVB 3-M IVB 5-M IVB 7-M english 5 Applications and techniques 5.1 Techniques 5.1.1 Picking up dry substances Do not pick up flammable substances. If used correctly, additional accessories, suction nozzles and suction hoses can enhance the cleaning action and reduce the cleaning effort. Effective cleaning is achieved if you follow just a few guidelines in combination with your own practical experience in special fields. Here are some basic tips.
IVB 3-M IVB 5-M IVB 7-M english 5.1.2 Picking up liquids Do not pick up flammable substances. Before liquids are picked up, always remove the filter bag/ waste bag and check that the float (IVB 3-M) or the water level limit (IVB 5-M/7-M) works properly. (See section 7.2.5 and 7.2.6 “Replacing the filter element“.) If foam appears, stop work immediately and empty the tank. To reduce the amount of foam, use foam killer Nilfisk-Alto Foam Stop (see section 9.5 „Accessories“ for order number).
IVB 3-M IVB 5-M IVB 7-M english 7 Maintenance 7.1 Maintenance plan After finishing work 7.2.1 Replacing the waste bag 7.2.2 Replacing the filter bag 7.2.3 Emptying dirt tank (IVB 3-M/5-M) 7.2.4 Emptying the dirt tank (IVB 7-M) 7.2.5 Replacing filter element (IVB 3-M) 7.2.6 Replacing filter element (IVB 5-M/7-M) 7.2 Maintenance work 7.2.1 Replacing the waste bag 1 2 When using IVB 3-M/5-M/7-M clean them thoroughly before replacing the waste bag - see sections 4.5 bzw.4.6.
IVB 3-M IVB 5-M IVB 7-M 7.2.2 Replacing the filter bag 1. Open the retaining clamps and remove the upper section of the cleaner from the dirt tank. 2. Carefully remove the filter bag connection from the inlet fitting. 3. Close the filter bag connection with the slide. 4. Dispose of the filter bag in accordance with legal regulations. 5.
IVB 3-M IVB 5-M IVB 7-M english 7.2.5 Replacing filter element (IVB 3-M) During the following work, ensure that dust is not unnecessarily spread around. Wear a P2 breathing mask. 1 3 2 4 1 6 2 1. Open the retaining clamps and remove the upper section of the cleaner from the dirt tank. Lay the upper section of the cleaner down with the filter element facing upwards. 2. Turn the filter holder anticlockwise (1) and remove it (2). 3. Place the protective filter bag1) over the filter element (3). 4.
IVB 3-M IVB 5-M IVB 7-M 7. Check the antistatic clamp (5) for damage and have it replaced by Nilfisk Advance Service if necessary. 8. Check that the control flap (6) for filter cleaning works properly. The control flap should move back and forwards easily. 9. Clean the level hose (7). 10.Fit a new filter element. 11.Fit the filter holder. Ensure that it is in the correct position. 12.Fit bar and close bar handle. 13.Dispose of the used filter element in accordance with legal regulations.
IVB 3-M IVB 5-M IVB 7-M english Fault ‡ The acoustic warning sounds. (Reduced suction power) Cause Remedy > Filter element is clogged. • See section 4.5/4.6 „Cleaning filter element“ and 7.2.5/7.2.6 „Replacing filter element“. > IVB 5-M/7-M only: Defective cleaning mechanism • Contact Nilfisk Advance Service ‡ No suction power during wet cleaning > Tank is full. (Float does not close the suction opening). • Switch off the cleaner. Empty the tank.
IVB 3-M IVB 5-M IVB 7-M 9.
Nilfisk-Advance A/S Sognevej 25 DK-2605 Brøndby Denmark Tel.: +45 43 23 81 00 Fax: +45 43 43 77 00 www.nilfisk-advance.