NEPTUNE 1, NEPTUNE 2 NEPTUNE 2 Special Operating Instructions 107145403 C
NEPTUNE 1 NEPTUNE 2 1 2 3 4 5 6 7 8 9 0 10 °F °C 85 30 105 40 50120 11 CUT OUT 60140 1 300 100 210 70 160 90 195 80 175 0 1% 2% 3% 4% 12 13 14 15 16 17 0 18 °F °C 85 30 105 40 50120 CUT OUT 19 60140 150 300 100 210 70160 80 175 90 195 0 1% 2% 3% 4% 20
NEPTUNE 1, NEPTUNE 2 NEPTUNE 2 Special Contents Symbols used to mark instructions ............................................................................................2 1 Important safety instructions ............................................................................................2 2 Description 2.1 2.2 Purpose ................................................................................4 Operating elements ..............................................................
NEPTUNE 1, NEPTUNE 2 NEPTUNE 2 Special Symbols used to mark instructions Safety instructions in these operating instructions which must be observed to prevent risks to persons are marked with this danger symbol. This indicates tips and instructions to simplify work and to ensure safe operation. Before using the high-pressurecleaner, be sure to also read the enclosed operating instructions and keep them within reach at all times.
NEPTUNE 1, NEPTUNE 2 NEPTUNE 2 Special If the mains power lead is damaged, to avoid hazards, this must be replaced either by the manufacturer or through his customer service or a similarly qualified person. Do not clean delicate parts made of rubber, fabric, etc. with the 0° jet. Keep some distance between high pressure nozzle and surface in order to prevent the surface from damage. CAUTION! Unsuitable extension leads can represent a source of danger.
NEPTUNE 1, NEPTUNE 2 NEPTUNE 2 Special Electrical equipment CAUTION! Never spray electrical equipment with water: danger for persons, risk of short-circuiting. Switching on the cleaner may cause voltage fluctuations. Voltage fluctuations should not occur if the impedance at the transfer point is less than 0.15 If in doubt ask your local electricity supplier. Maintenance and repair CAUTION! Always remove the plug from the mains plug socket before cleaning or carrying out maintenance work on the cleaner.
NEPTUNE 1, NEPTUNE 2 NEPTUNE 2 Special 2.2 Operating elements See fold-out page at front of these operating instructions. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. High pressure hose reel1) Top cover release Cannister for detergent Cable hook Spray lance Supply water connection Spray lance storage Hose hook Tank filler for fuel High pressure hose connection for machines without hose reel 11. 12. 13. 14. 15. 16. 17. 18. 19. 20.
NEPTUNE 1, NEPTUNE 2 NEPTUNE 2 Special 3.4 The Nilfisk Alto Antiscale dosing system is set by the factory. To adjust the water hardness we recommend that the inlet water is tested accordingly. Antiscale Use the schematic to find the right dosage of No Scale/anti stone and water, and add the mixture to the antiscale tank.
NEPTUNE 1, NEPTUNE 2 NEPTUNE 2 Special 3.8 devices of the machine can be destroyed. CAUTION! When using cable reels: 1. Due to the risk of overheating and fire, always unwind the power supply cord fully. Electrical connection 23 0V 400V 400V 23 0V 2% 3% 4% The cleaner may only be connected to a correctly installed electrical installation.
NEPTUNE 1, NEPTUNE 2 NEPTUNE 2 Special 1. Move main switch into the position 'Hot Water' (B) and select the required temperature on the temperature control 2. Unlock the spray gun and actuate it 4.2.2 Hot water operation (up to 100°C) IMPORTANT! In the case of appliances with a hose reel: In hot water mode, unwind the high-pressure hose fully from the hose reel, as otherwise the hose reel may become warped due to the effects of the heat. The burner switches on.
NEPTUNE 1, NEPTUNE 2 NEPTUNE 2 Special 5 Applications and methods 5.1 Efficient high pressure cleaning is achieved by following a few guidelines, combined with your own personal experience of specific cleaning tasks. Accessories and detergents, when correctly chosen, can increase the efficiency of your pressure washer. Here is some basic information about cleaning. Techniques 5.1.1 Soaking Encrusted or thick layers of dirt can be loosened or softened by a period of soaking.
NEPTUNE 1, NEPTUNE 2 NEPTUNE 2 Special 5.2.2 Vehicle Task Accessories Method Vehicle bodywork 1. Apply detergent to vehicle or equipment surfaces in Standard lance Detergent injection order to soften up dirt and grime. Apply from bottom Curved lances and unto top. In cases of particularly dirty vehicles, pre-spray derchassis washers with a product such as Allosil in order to remove traces brushes of insects etc, then rinse at low pressure and apply normal car cleaning detergent.
NEPTUNE 1, NEPTUNE 2 NEPTUNE 2 Special 6 After using the cleaner 6.1 Switching off the cleaner and disconnecting supply lines 1. Close water tap. 2. Activate spray gun without lance in order to empty all residual water in the system. 3. Turn the main switch to position „OFF“. 4. Pull out the plug from the electrical socket. 5. Squeeze the spray gun handle until the cleaner is depressurised. 6. Lock the safety catch on the spray gun. 7. Remove the water hose from the cleaner. 6.
NEPTUNE 1, NEPTUNE 2 NEPTUNE 2 Special 6.4 NEPTUNE 2 Storing the cleaner (below 0°C) A 6.5 Transporting the cleaner Store the cleaner in a dry room without danger of frost or protect as below: 1. Remove the water inlet hose from the cleaner. 2. Remove the spray lance. 3. Switch on the cleaner with the main switch in position "Cold Water". 4. Operate the spray gun. 5. Open the cover (A) 6. Gradually pour antifreeze (approx. 5 litres) into the water tank. 7.
NEPTUNE 1, NEPTUNE 2 NEPTUNE 2 Special 7 Maintenance 7.1 Maintenance plan 7.2 Maintenance work 7.2.1 Water filters Maintain water filters and fuel filters as required. A water filter is fitted on the water inlet to prevent large particles of dirt from entering into the pump. 1. Unscrew quick coupling with tool. 2. Remove filter and clean it. 3. Remount the filter and quick coupling 7.2.2 Maintenance of fuel filter 1. 2. 3. 4. 7.2.3 Emptying the fuel tank 1. Unscrew the cap 2. Remove the strain 3.
NEPTUNE 1, NEPTUNE 2 NEPTUNE 2 Special 8 Troubleshooting 8.
NEPTUNE 1, NEPTUNE 2 NEPTUNE 2 Special Indication lights Cause Remedy > Flashing light - Motor is overheated Turn main switch to position “OFF“ - let the machine cool down Remove/disconnect extension cable Possible phase failure on 3 phase variants1): have electrical connection checked Contact Nilfisk-ALTO Service > Flashing light - Faulty temperature sensor (B1) > > > > Flashing light - Flow sensor fault > > > > 8.
NEPTUNE 1, NEPTUNE 2 NEPTUNE 2 Special 9 Further information 9.1 Recycling the cleaner If the cleaner is discarded, make it unusable immediately 1. Unplug the cleaner and cut the power cord. 9.2 Guarantee 9.3 EU Declaration of Conformity Our general conditions of business are applicable with regard to the guarantee. Subject to change as a result of technical advances. The cleaner contains valuable materials that should be recycled. Therefore, make use of your local waste disposal site.
NEPTUNE 1, NEPTUNE 2 NEPTUNE 2 Special 9.4 Technical data Description Data General 1-22 EU 230/50/16 1-22 GB 230/50/13A 2-20 US 115/1/60/20 2-25 GB 230/1/50/13 2-25X GB 230/1/50/13 Tol. (±) Nom + Tol/- Tol Nom + Tol/- Tol Nom + Tol/- Tol Nom + Tol/- Tol Nom + Tol/- Tol Pressure Pwork @ Cylinder Head(bar) 10% 110 +11/-11 110 +11/-11 69 +7/-7 90 +9/-9 90 +9/-9 Flow. Qiec (l/h) 10% 540 +54/-54 540 +54/-54 568 +57/-57 640 +64/-64 640 +64/-64 Flow.
NEPTUNE 1, NEPTUNE 2 NEPTUNE 2 Special Description Data General 2-30X EU Special 400/3~/50 2-30 US 220240/1/60/20 2-33 EU 400/3/50 2-33X EU 400/3/50 2-33 NO 230400/3/50 Tol. (±) Nom + Tol/- Tol Nom + Tol/- Tol Nom + Tol/- Tol Nom + Tol/- Tol Nom + Tol/- Tol Pressure Pwork @ Cylinder Head(bar) 10% 155 +16/-16 138 +14/-14 170 +17/-17 170 +17/-17 170 +17/-17 Flow. Qiec (l/h) 10% 600 +60/-60 681 +68/-68 630 +63/-63 630 +63/-63 630 +63/-63 Flow.
NEPTUNE 1, NEPTUNE 2 NEPTUNE 2 Special Description Data General 2-16 Gerni 240/1/50/10 2-26 Gerni 240/1/50/15 2-25 KR 220/1/60/15 2-40 EXPT 220,440/3/60 2-40X EXPT 220,440/3/60 Tol. (±) Nom + Tol/- Tol Nom + Tol/- Tol Nom + Tol/- Tol Nom + Tol/- Tol Nom + Tol/- Tol Pressure Pwork @ Cylinder Head(bar) 10% 100 +10/-10 145 +15/-15 125 +13/-13 185 +19/-19 185 +19/-19 Flow. Qiec (l/h) 10% 400 +40/-40 530 +53/-53 540 +54/-54 730 +73/-73 730 +73/-73 Flow.
Nilfisk-ALTO www.nilfisk-alto.